General Information Constructional features Type selection Safety Valves Valves for technical gases Block Connection System

Piston Compressors hydraulically driven

Constructional features

Construction

Hydraulically driven, dry-running HOFER piston compressors are designed for easy maintenance and allow a lubricant-free compression of non-corrosive gases, which are free from solid particles, such as hydrogen, helium, argon, nitrogen, carbon dioxide and ethylene.

The maximum discharge pressure of the standard design is approx. 14.500 psi (1.000 bar). For higher working pressures up to 65.250 psi (4.500 bar), special designs are available.

This compressor type is built in an easy to maintain construction. A piston packing can be replaced in approx. 10 to 30 minutes, depending on the compressor size.

Principle of working

The special construction and design of the piston packing allows to operate completely without the lubrication of these sealing elements at higher discharge pressures, although under normal circumstances such a lubrication is absolutely required.

The gas piston gets the required sealing and sliding properties by the design of the packing structure with the materials specially developed for this purpose. The gas space and the gas to be compressed are kept free from undesirable lubricants.

HOFER piston compressors of the TKH type series are preferably designed in a two-stage respectively one-stage double-acting design. The unit is driven by oil-hydraulics. The hydraulic cylinder is positioned between the first and second stage. A hydraulic pump with controllers alternating pressurises the hydraulic cylinder with the hydraulic oil. Proximity limit switches activate the stroke reversion.

Mixing of both media is excluded due to the separation of the hydraulic and gas chamber and by use of double seals.


Principle of working piston compressor non-lubricated

The force required for gas compression is generated by the oil pressure and the corresponding ratio of piston diameters.

The capacity is regulated by the piston speed (number of strokes) through varying of the flow rate of the pump. The frequency of strokes and, thus, the suction capacity of the compressor can be continuously regulated between 0% and 100% via a standard analogue signal.

Upon request, instruments for the detection of gas and oil leaks can be integrated at this point. This allows to permanently monitor the condition of gas- and oil-side seals. The gas which is compressed in the different stages is cooled by the respective downstream inter-stage and after cooler. Here, the temperature difference is approx. 10 K in relation to the cooling water inlet temperature. Usually, the hydraulic unit is also connected to this cooling circuit.

Installation of HOFER piston compressors in hazardous areas

For the use of the compressors in hazardous areas, two alternatives can be supplied:

  1. Installation of the cylinder set in the hazardous area (zone 2 or 1) and installation of the hydraulic system in the non-hazardous area. The hydraulic oil unit is connected through a gastight wall.
  2. Installation of the cylinder set and the hydraulic unit in the non-hazardous area (zone 2).

Capacity, compression ratios, pressure stages

The suction capacity of the compressor is determined by the suction pressure, the discharge pressure and the frequency of strokes. For different models please refer to the attached tables (other performance data upon request). The stated driving powers apply to the maximum operating data.

Equipment

The HOFER compressors of the TKH model series can be supplied as a compressor without accessories or turn-key as a complete operational unit with all necessary devices, fittings and instruments.

Acceptances and certifications

The standards and directives applicable in the European Community

  • Directive for Machinery 98/37/EG
  • Pressure Equipment Directive 97/23/EG
  • ATEX Directive 94/9/EG
  • Low Voltage Directive 93/68/EWG

as well as in above mentioned applicable standards are the basis of our construction and design.

Compliance with the applicable directives is confirmed by the conformity declaration respectively the manufacturer's declaration and the CE marking of the compressor.

US standards: For the American market, the applicable US regulations and standards are complied with. Prior to delivery, each HOFER piston compressor is subjected to a test run under operating conditions for several hours. Upon request, the customer participates the test run.

Top   ^^ 

Print Print

Topics

Our brochure
piston compressors



Download:
» Piston Compressor.pdf  (1,9 MB)



Technical questionnaire

We are pleased to create for you a special offer without obligation for a compressor of your demands:
» Questionnaire



Technical animation




HOFER
Hochdrucktechnik GmbH
Ruhrorter Straße 45
D-45478 Mülheim an der Ruhr
Phone +49-(0)208-4 69 96-0